Skip to content

Transition metals lab for A Level chemistry: practical with sample results (free PDF download)

Quick answer: Transition metals are d-block elements that form ions with a partially filled d subshell. This Chemistry 11-12 lab on transition metals gives the aim, the equipment, the safety points, a step-by-step method, sample results and 8 analysis questions; the answers are on a separate page and the lab sheet is a free printable PDF.

Transition metals lab for A Level chemistry: practical with sample results (free PDF download)

What colours do copper(II) complexes show when the ligands change, and how can a colorimeter turn colour into a concentration? You will make four complex ions, explain the colour changes, and use a calibration graph to find the concentration of an unknown ammonia complex solution.

Level: Chemistry grades 11-12 (A Level · IB · Class 11-12) · Curriculum: A Level 3.2.5

Aim

To make different copper(II) complex ions by ligand substitution, record their colours and use a colorimeter to find the concentration of an unknown solution of tetraamminecopper(II).

Equipment

  • 0.10 mol dm⁻³ copper(II) sulfate solution
  • Dilute and 1 mol dm⁻³ ammonia solution, concentrated hydrochloric acid (teacher dispensed)
  • Test tubes and rack, droppers, 10 cm³ measuring cylinder, volumetric flask or graduated pipettes
  • Colorimeter or phone light sensor with orange filter and cuvettes

Safety

Safety

Wear goggles. Concentrated hydrochloric acid and ammonia vapours irritate the lungs: use only in a ventilated area or fume cupboard. Copper(II) compounds are harmful, so wash hands and dispose of waste in the labelled container.

Method

Row of five test tubes with copper solutions: pale blue, pale blue with precipitate, deep blue, yellow-green and pale bluetube 1tube 2tube 3tube 4tube 5
Five tubes used to compare copper(II) complexes.
  1. Put 2 cm depth of copper(II) sulfate in tubes 1 to 5. Tube 1 stays as the control.
  2. To tube 2 add 5 drops of ammonia, record the colour; add excess ammonia to tube 3 and record.
  3. To tube 4 add 2 cm of concentrated hydrochloric acid and record the colour; pour half of it into tube 5, add water drop by drop and record the colour.
  4. Prepare standards of [Cu(NH₃)₄(H₂O)₂]²⁺ by diluting a stock solution to 0.020, 0.040, 0.060 and 0.080 mol dm⁻³ and measure the absorbance of each at 600 nm. Measure the unknown, which was diluted 5.0 cm³ to 25.0 cm³.

Results

TubeReagent addedObservation
1nonepale blue solution
2few drops ammoniapale blue precipitate
3excess ammoniadeep blue solution
4conc. HClyellow-green solution
5half of tube 4, then waterturns blue again
Concentration (mol dm⁻³)0.0200.0400.0600.080unknown
Absorbance0.150.310.440.600.36

Analysis questions

Question 1 Colour changes

Write the formula of the copper complex responsible for the colour in tubes 1, 3 and 4.

Question 2 Equations

Write ionic equations for the reactions in tubes 2 and 3.

Question 3 Explain the change in tube 4

Explain why the coordination number changes in tube 4 and why adding water in tube 5 reverses the colour.

Question 4 Calibration graph

Plot absorbance against concentration for the standards and describe the graph.

Question 5 Molar absorptivity

Calculate the slope of the line through the origin for these data and say what the slope tells you about the complex.

Question 6 Unknown solution

Use the graph to find the concentration of the diluted unknown and then of the original solution.

Question 7 Why a filter

Explain why an orange filter (about 600 nm) is chosen for the blue complex.

Question 8 Improvements

Suggest two improvements to make the concentration more precise.

See the transition metals lab answers

Physics and chemistry textbooks to download in PDF, from grade 6 to AP Physics and AP Chemistry